17
CODING TRANSMITTERS
CODING TRANSMITTERS INTO RECEIVER
Transmitters can be programmed into the gates receiver to do two
functions: the full Open/Stop/Close cycle, and partly open gate for
PEDestrian access. The memory in the receiver can store up to 30
different remote control transmitters.
Note: Make sure to connect the battery to the transmitter in the
correct polarity.
STORING TRANSMITTER CODE FOR O/S/C
1. Press and hold the SW1 button on the receiver (Fig. 15).
2. Press the button on the transmitter you would like to use to
control the gate for approximately two seconds.
3. Release. Pause for two seconds. Press the same button again on
the transmitter for approximately two seconds.
4. Release the SW1 button.
5. Press the transmitter button to test if it operates the gate.
Note: If required, all four transmitter buttons can be coded to do
the same function.
STORING TRANSMITTER CODE FOR PED ACCESS
1. Press and hold the SW2 button on the receiver (Fig. 15).
2. Press the button on the transmitter you would like to use to
control the pedestrian access for approximately two seconds.
3. Release. Pause for two seconds. Press the same button again on
the Transmitter for approximately two seconds.
4. Release the SW2 button.
5. Press the Transmitter button to see if it operates the gate.
IMPORTANT: The Pedestrian Access Cycle Time must be set to
to activate this feature.
STORING ADDITIONAL TRANSMITTER(S) FROM A
REMOTE LOCATION
Using this method you do not need to have direct access to the
control box or receiver. However, you do need a transmitter that is
already coded to the controller’s receiver.
NOTE: The gate must be activated when the step below is
performed. The moving gate confirms that the correct button was
pressed and the transmitter is in range of the opener.
1. Press the button on a pre coded transmitter and release (Fig. 16).
2. Using a small pin press and hold the coding hole for 2 seconds
(Fig. 17).
3. Within 10 seconds press the button on the new transmitter for
approximately two seconds (Fig. 18).
4. Release. Pause for two seconds. Press the same button again for
approximately two seconds.
5. Wait ten seconds and test to confirm that coding was successful.
DELETING STORED TRANSMITTER CODES
TO DELETE ONE TRANSMITTER
1. Press and hold the SW1 button on the receiver. (Pressing SW2
button will only delete PED function and not OSC for that
transmitter).
2. Press the button (one of four) on the transmitter you would
like to delete from the receiver for two seconds.
3. Pause for two seconds. Press the same button again 2 secs.
4. Release the SW1 button.
5. Press transmitter button to confirm it does not operate the gate.