Vista de pagina 14
15
AUTO-CLOSE MODE
Auto-close mode automatically closes the gate after a preset time
once the gate has reached its desired open position. The controller
starts to close the gate when the count down has expired. The
timer can be suspended by activating a suspending input (which
inputs 'suspend' depends on which auto-close mode is selected).
When the input is deactivated the auto-close timer is reset and the
count down recommenced. Auto-close functions are temporarily
disabled by certain actions. When this happens the controller will
not auto-close the gate until the user performs some action to
re-enable the function. Details about the three auto-close modes
follow.
STANDARD AUTO-CLOSE
This mode is selected by placing the mode selection switch
labeled “STANDARD AUTO-CLS” into the “ON” position.
When selected the gate will auto-close 30 seconds after being
fully opened. The following gives details about this auto-close
mode.
Auto-closes after being:
z Fully opened. (except when the gate is reversed to the open
position after a motor overload is detected while closing)
Countdown suspended by:
z The P.E. input being active.
z The OPN input being active.
Function temporarily disabled by:
z Activating the STP input while the gate is open.
z A motor overload causing the gate to reverse open.
Function re-enabled by:
z Activating the OPN input while the gate is open.
z Activating the OSC input, in SWIPE mode, while the gate is
open.
z By activating any input which cases the gate leaf to start to
close. The auto-close function will then be enabled once the
gate is re-opened.
The standard delay time of 30 seconds can be altered, see
STANDARD AUTO-CLOSE DELAY TIME, on page 16.
PEDESTRIAN ACCESS AUTO-CLOSE.
This mode is selected by placing the mode selection dip-switch
labeled “PEDESTRIAN AUTO-CLS” into the “ON” position.
When selected, the gate leaf will auto-close 15 seconds after
being opened for pedestrian access.
Auto-closes after being:
z Driven to the programmed pedestrian access position. (Except
when the gate leaf is reversed after a motor overload is
detected.) Reversing during pedestrian access is only
implemented when special PED modes are selected.
z Stopped by the P.E. input when closing after pedestrian access
(standard PED mode only).
Countdown suspended by:
z The P.E. input being active.
z The PED input being active.
Function temporarily disabled by:
z Activating the STP input while the gate leaf is in the
programmed pedestrian access position.
z Activating the STP input in condition 2 of 'Auto-closes
after being above.
z A motor overload causing the gate to reverse back to the
programmed pedestrian access position. (Reversing during
pedestrian access is only implemented when special PED
modes are selected.)
Function re-enabled by:
z Activating the PED input, in SWIPE mode, while the gate is in
the programmed pedestrian access position. Activating the
PED input and causing the gate leaf to start to close.
The standard delay time of 15 seconds can be altered, see section
PEDESTRIAN ACCESS AUTO-CLOSE DELAY TIME on page
16.
P.E TRIGGERED AUTO-CLOSE
This mode is selected by placing the mode selection dip-switch
labeled “P.E. TRIGGERED AUTO CLS” into the “ON” position.
When this auto-close mode is selected, the gate will auto-close
after the P.E. input has been activated and released since:
1. The gate was last closed
2. The P.E. triggered auto-close function
was re-enabled after being disabled.
3. The SWIPE input was activated.
Auto-closes after the P.E. input has been activated and then
released and the gate:
z Is fully opened. (except when the gate is reversed to the open
position after a motor overload is detected while closing).
z The gate has been stopped by the P.E. input.
Countdown suspended by:
z The P.E. input being active.
z The OPN input being active.
Function temporarily disabled by:
z Activating the STP input.
z A motor overload causing the gate to stop or reverse open.
Function re-enabled by:
z Activating the OPN input while the gate is open.
z Activating the SWIPE input.
z By activating any input which cases the gate to start to open or
close. The auto-close function will then be enabled once the
gate is re-opened or the P.E. input causes the gate to stop.